4-Channel Loop Detector
Card plug for rack system
Home >
Products > Traffic
Light Installations > Loop Detector IG224/4
Application range |
Features |
Function description |
Classification function
Synchronization |
Technical data |
PDF download
Application range
- Signal output for traffic light installations
- Counting of traffic
- Bus classification, car / lorry classification
- Special options
- Detection of traffic jams
- Speed measuring
|

Detail view
|
Features
- High noise immunity
- Permanent loop control
- Ferrit control
- Card plug-in for rack system with direct connector
- Comfortable operation via manual terminal or PC software, diverse
adjustability
- RS485 interface and RS232 interface
- Operational parameters are saved in EEPROM
- Low power consumption
- Various output functions:
- Presence signal
- Impulse signal
- Directional signal
- Adjustable switch on/off delay
- NEMA (USA) Standard
- Loop lead-in wiring up to 550 m (with ø 0.8 mm)
- Canoga-compatible version available (e.g. C424, C824)
Function description
The 4-Channel Loop Detector IG 224/4 was especially designed for traffic
applications and stands out for its multitude of special functions. Like
the series IG224 and IG224/4, loops are controlled in the noise immune
multiplex mode.
The oscillator can be adjusted to very low loop inductivities by a jumper (single-turn loops).
Inductivities of 400 µH or more a resistance of 40 Ohm is permitted(corresponds to approx.
550 m feed cable with ø = 0.8 mm). The front-side service interface can be used to adjust via laptop
(service software IGBT) multiple channel parameters like: sensitivity, measuring time, hold time,
operational frequency, switch on/off delay, directional logic and oversampling.
The software is also designed for the diagnosis of loops and detectors,
and for activating special functions.

Classification function
A bus detection can be implemented by using a special loop (10 m x 2.5 m).
The value of attenuation is the decisive criterion.
For smaller loops (loop length: 1.0 - 2.5 m) a simple differentiation between car / lorry can be realised.
Synchronization
Crosstalk of loops and their feed cable can be eliminated by synchronizing
up to 30 detectors.
Dimensions


|